Single Phase Reset Din Rail Energy Meter hmanga siam a ni

Single Phase Reset Din Rail Energy Meter hmanga siam a ni

Single Phase Reset Din Rail Energy Meter hi chenna in, sumdawnna, leh multi{2}}tenant environment-a sub-metering dik tak, nghet tak, leh man tlawm zawka siam theihna tura engineer a ni.
Inquiry thawn rawh .
Hrilhfiahna
Technical Parameters 1000 a ni.

Product chungchang tlangpui

 

Single Phase Reset Din Rail Energy Meter hi chenna in, sumdawnna, leh multi{2}}tenant environment-a sub-metering dik tak, nghet tak, leh man tlawm zawka siam theihna tura engineer a ni. Standard compact DIN rail layout a nei a, modular distribution panel leh energy management system-ah rang taka inzawmkhawm theih a ni.

Kan ISO9001:2015 certified production system hnuaia siam, unit tin hian khawvel pum huapa thawn chhuah hmaa out{4}}of{5}}the-box measurement consistency a awm theih nan IEC standard angin 100% dual-stage testing leh calibration khauh tak an nei a ni.

product-1200-675

 

Technical lam thil chi hrang hrang

 

Parameter chi hrang hrang a awm

Thil chiang tak takte

Display Method a ni

LCD Display(backlight nei) a ni.

Voltage Rated a ni

220V

Rated Current a ni

5-60A

A dikna Class

Class 1.0 a ni

Net Weight a ni

0.2kg vel a ni

Install dan tur

35mm rail hmanga siam a ni

Dimension hrang hrang

78×36×65mm (±0.8mm) a ni a, a man pawh a tlawm hle.

Zinzia

50Hz / 60Hz a ni

Impulse chu a awm reng a ni

1600 imp/kWh emaw 3200 imp/kWh emaw a ni thei

Power hman dan tur

2W / 10VA aia tlem emaw, a tlukpui emaw a ni

 

Wiring & Protection chungchanga hriat tur pawimawh te:Direct-connection wiring a support a, terminal chiang taka ziak, straightforward integration atan a support. Standard electrical cabinet-a dust protection rintlak tak neih theihna turin IP51 emaw IP20 tlukpui protection rating (shell configuration a zirin) hmanga design a ni.

 

Product-a thil pawimawh ber berte

 

  • IEC 62053-21 hnuaia Class 1.0 accuracy standard zawm hian sub-billing verification rintlak tak neih theihna turin active energy measurement nghet tak a tichiang a ni.
  • Integrated manual push-button reset function hmang hian property manager te chuan tenant thar emaw, mimal charging session emaw tan short{1}}term tracking chu rang takin an restart thei a ni.
  • Standard 35mm DIN rail mounting layout hian modular distribution board awm tawh tam zawk leh compact electrical enclosure-ah seamless integration a siam a ni.
  • V0-grade flame-retardant polycarbonate enclosure hian sumdawnna hmun harsa takah temperature resistance sang tak leh structural durability a pe a ni.
  • LCD display chiang tak, built-in backlight neia thuam a ni a, hei hian electrical closet eng tlem lo emaw sub{1}}panel emaw-a chhiar awlsamna a siamsak a ni.
  • Passive pulse output terminal-a siam- hian remote data collection hmanrua leh central energy management system-te nena inzawmna awlsam tak a siamsak a ni.

 

product-1200-675

 

Ordering & Model thlan dan tur kaihhruaina

 

I thil lei dan awlsam zawk nan RFQ i submit dawnin i duhzawng configuration kha tarlang la:
Model KA-SR01: a ni.5(60)A, 1600 imp/kWh, LCD leh Backlight hmanga siam a ni

Model KA-SR02: a ni.5(60)A, 3200 imp/kWh, LCD leh Backlight hmanga siam a ni
(Customizable parameters current range, voltage ratings, leh private labeling te chu dil theih a ni).

 

product-1200-439

 

Target Dilna hrang hrang

 

Standard utility meter ang lo takin, he manual-reset energy meter hi specialized commercial leh sub{1}}metering scenario atan a tha ber a ni:
Rental Property leh Apartment hrang hrang:In neitute chuan tenant thar a rawn insawn chuan awlsam takin meter chu zero-ah an reset thei a, mimal billing cycle te chu an track thei a ni.

EV Charging Station Sub-metering hmanga chhut a ni.Electric lirthei charging session khat chhunga energy hman dik tak chu track rawh.

Co-hnathawhna hmun & Office insem:Startup booth pakhat zel emaw, hmanrua insem emaw-a power hman dan bik enfiah leh bill.

Marina, Camping leh Caravan Park hrang hrangah te:Lawng, RV, leh mobile home te tana temporary power connection tracking atan a tha hle.

 

Factory atanga thil siam chhuah chakna

 

I supply chain stability hi kan physical manufacturing infrastructure hian a pui a ni:
Facility Scale: 1.1.1,600 m2-a zau electrical instrument siamna hmun bik chu kum 1994-a din a ni (kum 30 chuang zet siamna lama thiamna nei tawh).

Production Line hrang hrang: 1.1.Active assembly line 3 leh automatic packaging line 2, kum khata single-phase meter 1,000,000 leh three{8}}phase meter 500,000 vel verified capacity pe thei a ni.

Quality Control: 1.1.100% dual-stage testing workflow-ah hian automatic aging test leh multi-position computerized calibration bench verification neih a ni a, chu chu final automated sealing leh packaging hmain a ni.

 

Compliance & Certification Dossier pek a ni

 

International import customs clearance leh regional project approval neihna atana mamawh technical dossier kimchang kan pe a ni. Document awmsa te chu:
• CE Certificate (European Market nena inmilna) 1.1.

• RoHS & REACH Material Test Report (Environment zawm dan) te chu a hnuaia mi ang hian a ni.

• ISO9001:2015 Factory Audit Report & Quality Management Certification pek chhuah a ni

 

FAQ

 

Q: I meter te hi European leh international market tan certified a ni em?

A: Ni e. He series hi CE certified kim a ni a, IEC 62053-21 Class 1.0 dikna leh RoHS environmental directives zawm a ni a, khawvel market-ah customs clearance leh regulatory compliance mumal tak a awm theih nan a pui a ni.

Q: Bulk wholesale order-a i production capacity leh delivery lead time chu engzat nge ni?

A: Kan 1,600 m2 facility leh active assembly line 3 hmanga thlawp, standard B2B wholesale order hi ni 15 atanga ni 30 chhungin thawn chhuah a ni tlangpui a, chu chu i customization mamawh bik a zirin a ni.

Q: Engtin nge batch lian tak takah measurement consistency i vawn reng?

A: Mihring tihsual hi high-level automation hmangin tih tlem a ni. Unit pakhat zel hian Class 1.0 limit chhunga error margin khauh taka dah turin kan multi-position computerized calibration systems--a mimal accuracy check te pawh huamin, mandatory dual-stage automated testing process-an paltlang vek a ni.

Q: OEM/ODM customization leh private labeling i pe em?

A: Ni e. Kan in-house automated laser-marking machinery hmang hian i brand logo, current/voltage parameter bikte chu a nghetin kan engrave thei a, i sumdawnna mamawh angin regional packaging pawh kan siam danglam thei bawk.

Q: International distributor te tan eng warranty leh defect policy nge i neih?

A: Kan quality hi kan back a, kan thawn chhuah ni atanga thla 18- factory warranty kan pe thin. Manufacturing defects emaw quality non-conformances verified a awm chuan direct product replacement emaw credit allocation emaw hmangin i order batch lo awm turah chinfel a ni.

hot tags .: single phase reset din rail energy meter, China single phase reset din rail energy meter siamtu, supplier, factory